(608) 346-2392 info@innalytical.com
Electric Motor Assembly

Electric Motor Assembly

The challenge was to maintain the the air gap between the stator and rotor of an electric motor while the end plates were clinched to the stator assembly. The solution was to create a shim pack assembly that was attached to the rotor before it was inserted into the...
Circuit Breaker Test

Circuit Breaker Test

The challenge was to replace a manual test station for circuit breakers. Operators were manually loading and unloading circuit breakers into sockets of a test stand and then sort the good and reject units based on a series of lights. Repetitive motion was a constant...